Operation
5.4.1.1
The automatic level adjustment determines a suitable combination of internal sensor parameters for the cur-
rent optical situation. The primary factor here is the level setting for the illumination LED:
colorSENSOR CFO
Automatic Level Adjustment
This starts an automatic level setting process
INT
TEACH
AUTO
i
CLR
OPT
GATE
1
TEACH
2
HOLD
3
ESC
MULTI
4
TOL
CLASSIFY
5
SPHERE
6
7
CYLINDER
BOX
8
The automatic level adjustment process requires several seconds. During this
time, output LEDs 1 - 8 flash alternately, i.e. the even numbered LEDs and the
INT
TEACH
uneven numbered LEDs flash on and off together in groups.
AUTO
i
CLR
OPT
GATE
1
TEACH
2
HOLD
3
ESC
MULTI
4
TOL
CLASSIFY
5
SPHERE
6
CYLINDER
7
BOX
8
Press the AUTO key for less than 2 sec.
The level for the sensor parameters should be set for the brightest color to
be tested.
The automatic level adjustment sets the photo receiver to 80 % saturation.