Anhang | API Communication with Controller (Version 0.7.1)
A 3.5.3.40 /api/system/factory-reset
Sensor reset to factory settings followed by reboot:
Restoration of original firmware version
All settings are reset
It is possible to reset the settings without rebooting via /api/settings/.
POST
No attributes are expected
Error codes:
LPLC.system.action_failed
A 3.5.3.41 /api/system/reboot
Reboot sensor.
POST
No attributes are expected.
Error codes:
LPLC.system.action_failed
A 3.5.3.42 /api/system/time
Query and change of time settings
GET
The following attributes are provided:
Attribute
now
timezone
ntp_servers
default_ntp_serv-
ers
PUT
All attributes can be written.
colorSENSOR CFO
Model
Content
Text
Representation of date corresponding to ISO 8601
Text
Name of currently configured time zone
Text list
One or more currently used time servers (IP / Hostname)
Text list
Specified standard NTP server
Page 118