SINAMICS S150
Engineering Information
Line supply voltage
Output power at
400 V resp. 690 V
With dv/dt filter plus VPL (option L10)
380 V – 480 V 3AC
110 kW - 800 kW
500 V – 690 V 3AC
With sine-wave filter (option L15)
380 V – 480 V 3AC
110 kW - 250 kW
500 V – 690 V 3AC
110 kW - 132 kW
Permissible motor cable lengths for SINAMICS S150 (continued)
When two motor reactors are connected in series, the permissible cable lengths can be increased even further to
525 m with shielded cables and 787 m with unshielded cables.
A second motor reactor is not a standard option and may require an additional cabinet. A second motor reactor is
therefore available only on request.
SINAMICS Engineering Manual – May 2008
312/396
© Siemens AG
e.g. Protodur NYCWY
75 kW - 1200 kW
Maximum permissible motor cable length
Shielded cable
300 m
300 m
300 m
300 m
Unshielded cable
e.g. Protodur NYY
450 m
450 m
450 m
450 m