3-6-3 Expiry date/time settings: LMT
Configures the "expiry" function used to mark the date with a specified period added or subtracted to/from the current date.
⿎ Setting request data / response data for readout
Start
LMT
code
command
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request
Start
LMT
code
⿎ Data description
Data length
Name
[byte]
Expiry time No.
Periods
Expiry time unit
Today included
Total data length
⿎ Example of command settings
Condition:
Expiry time No. = 1, Periods = 6, Expiry time unit = 2, Today included = 0
• Setting
Transmission data
• Readout
Transmission data
Response data
• With LP-400/V compatible command mode, the expiry time numbers 5 to 16 and global expiry time numbers 21 to 32
cannot be set and readout.
[Expiry time No.] [Periods]
Sub
[Expiry time unit] [Today included]
[Expiry time No.]
R
1-byte
Data contents
"1"–"4": Expiry date/time 1 to 4
1
"5"–"8": Global expiry date/time 17 to 20
4
"-999"–"+999"
"0": Year
"1": Month
1
"2": Date
"3": Hour
"4": Minute
"0": Today not included
1
"1": Today included
7
The data length is fixed.
[STX]
LMT
[STX]
LMT
[STX]
LMT
ME-LP-GS-SR-COMP-3
7-byte
(Check sum)
S
1+00620
[CR]
R
1
[CR]
A
1+00620
[CR]
(Check
End code
sum)
End code
Remarks
It is the period added or subtracted to/
from the current date and time.
It is the unit of the period added or
subtracted to/from the current date and
time.
Specifies whether or not to include
today in the base date for addition or
subtraction.
It is valid when the expiry time unit is
year or month.
81