Remote Mode Settings - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

1-1-4 Remote mode settings

To control the laser marker externally using I/O or serial communication commands, set the operation mode to the remote
mode with one of the following methods.
Select the method to switch to the remote mode on the system settings screen of Laser Marker NAVI smart. Refer to "1-1-3
Settings before external control" (P.14).
Remote mode switching by Laser Marker NAVI smart
Click the "Laser Marker Operation" tool of Laser Marker NAVI smart. Then, click
"Remote mode ON/OFF". Click "Yes" on the confirmation screen to switch the
laser marker to the remote mode.
• The "Remote mode ON/OFF" button is available when the following screens are
selected with the online connection established.
• Marking settings screen
• Operator settings (restricted) screen
• Monitor screen
Startup the laser marker in the remote mode (Laser Marker NAVI smart can switch the remote mode)
When you turn ON the key switch of the laser marker, the system starts in the remote mode. Use the remote mode
switch button of Laser Marker NAVI smart for releasing and resetting the remote mode.
• If you want to start up the laser marker in the remote mode, you need to configure the settings on the system settings
screen of Laser Marker NAVI smart in advance.
• If you have configured the laser marker to start up in the remote mode, you cannot switch the remote mode from I/O.
Remote mode switching using I/O
Turn ON REMOTE IN (X4) of the I/O terminal block on the
controller.
• To enable switching to the remote mode by REMOTE IN (X4) on the I/O terminal block, you need to configure the
settings on the system settings screen of Laser Marker NAVI smart in advance.
• If you have configured the remote mode switching method to the I/O terminal block, you cannot switch the remote mode
from the Laser Marker NAVI smart screen.
WARNING
• If the laser marker is set to enter the remote mode at startup or by I/O control,
construct a manual resetting system to re-pump the laser when the laser
pumping is turned to off due to an emergency stop or an interlock.
ME-LP-GS-SR-COMP-3
PLC, etc.
REMOTE IN
OUTPUT
X1
Y1
X2
Y2
X3
Y3
X4
Y4
X5
Y5
X6
Y6
X7
Y7
I/O terminal block
17