Laser Frequency / Pulse Cycle: Mpl - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-12-3 Laser frequency / pulse cycle: MPL

Sets the laser frequency (LP-GS/LP-RC) or pulse cycle (LP-RF/LP-RV) for the current file.
• The settings by this command are applied to all objects in the file. With LP-RF/LP-RV series, if you want to change the
pulse cycle correction value of the specified object only, set the pulse cycle correction by each object setting.
• With LP-400/V compatible command mode, the available setting range of the pulse cycle for LP-RV series is limited. If
the setting value exceeds the limit, it is not possible to readout the settings by this command.
• For LP-RV series, the pulse duration is set to 30ns when you set the pulse cycle by this command.
⿎ Setting request data / response data for readout
Start
MPL
code
command
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
MPL
code
⿎ Data description
Data length
Name
Laser frequency
or
Pulse cycle
Total data length
⿎ Example of command settings
Condition:
LP-GS series, Laser frequency=20
• Setting
Transmission data
• Readout
Transmission data
Response data
Condition:
LP-RF series, Pulse cycle = 40
• Setting
Transmission data
• Readout
Transmission data
Response data
[Laser frequency/Pulse cycle]
Sub
LP-GS/LP-RC: 1-byte
LP-RF/LP-RV: 4-byte
R
(Check sum)
End code
Data contents
[byte]
Model
LP-GS051(-L)
LP-GS052
1
or
LP-RC350S
4
LP-RF200P
LP-RV200P
1
Fixed length.
or
• LP-GS/LP-RC series: 1-byte
4
• LP-RF/LP-RV series: 4-byte
[STX]
MPL
[STX]
MPL
[STX]
MPL
[STX]
MPL
[STX]
MPL
[STX]
MPL
ME-LP-GS-SR-COMP-3
Setting range
• For LP-GS/LP-RC series, set the
"0": 5 kHz
laser frequency (1-byte).
"1": 10 kHz
• For LP-RF/LP-RV series, set the
"2": 20 kHz
pulse cycle (4-byte).
"3": 40 kHz
• For LP-RV series, the pulse duration
is set to 30ns when you set the
"05.0"–"50.0" [μs]
pulse cycle by this command.
"01.2"–"99.9" [μs]
S
2
[CR]
R
[CR]
A
2
[CR]
S
40.0
[CR]
R
[CR]
A
40.0
[CR]
(Check
End code
sum)
Remarks