3-11 On-the-fly Marking Commands

3-11-1 Motion settings: TRG

Supported model: LP-RC series / LP-RF series / LP-RV series
Sets the basic configuration of the on-the-fly marking, such as moving direction and etc. The settings are applied to all
marking files.
⿎ Setting request data / response data for readout
Start
TRG
code
command
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
TRG
code
⿎ Data description
Name
Moving direction
Line speed control
Trigger mode
Total data length
• Any of the following functions that are not available with on-the-fly marking are configured.
• Link control with external image checkers
• Overwriting interval
• Skip marking of 2D code (Setting of module marking order)
• When the trigger mode is set to Marking at regular intervals, those functions are also not available.
• Registered characters (via I/O)
• External Offset including SEO command
• Characters specified by SIN command
• Counter reset at date change
• The setting changed by this command is saved in the laser marker without overwriting to the file.
• The "Delay distance" which was specified in LP-400/V series is corresponding to "Trigger detecting position" and
"Workpiece reference boundary" in this product. If you want to set those parameters, switch the command mode to the
standard mode by RMS command.
[Moving direction] [Line speed control]
Sub
R
(Check sum)
Data length
Data contents
[byte]
"0": Marking to static object
"1": +X to -X (Left)
1
"2": -X to +X (Right)
"3": +Y to -Y (Front)
"4": -Y to +Y (Back)
"0": Fixed speed
1
"1": Encoder input
"0": Single trigger
1
"1": Marking at regular intervals
3
Fixed length.
ME-LP-GS-SR-COMP-3
[Trigger mode]
3-byte
End code
• Specify "0" to disable on-the-fly
• The direction of X/Y axis is defined by
With LP-400/V compatible command
mode, "2 sensors input" cannot be set and
readout.
• "Single trigger" corresponds to "trigger
• With LP-400/V compatible command
(Check
End code
sum)
Remarks
marking.
the head direction setting in System
settings.
marking" of LP-400/LP-V series.
mode, "multiple triggers" cannot be set
and readout.