Time Hold Input And Date Gap Output; Counter End Output - Panasonic LP-M Series Maintenance Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

3-5-6 Time hold input and date gap output

Actual date
ON
TIME HOLD IN
OFF
ON
TRIG. IN
OFF
ON
MARKING OUT
OFF
ON
READY OUT
OFF
ON
GAP OUT
OFF
• The time at system startup is held when the laser marker is turned to on with the TIME HOLD ON.
• If the TIME HOLD is set ON, the time is held in spite of switching the file No.
• If the TIME HOLD ON/OFF is switched in short time, each ON/OFF hold time should be more than 2 seconds.

3-5-7 Counter end output

READY OUT
TRIG. IN
MARKING OUT
COUNTER END OUT
(CEND 0 to 7)
Item
Period
T1
10 ms or more
• The counter end output remains turned ON with the shutter open until the next marking trigger is input. When you close
the shutter, the counter end output turns OFF.
• When "Step & Repeat counter at each step" function is set, counter end output is invalid.
Day 1
Example: 15 o'clock at Day 1
Marking with
the time at
ON
(3 p.m. at Day 1)
ON
OFF
ON
T1
OFF
ON
OFF
The end value is marked.
ON
OFF
Remarks
Keep the ON status for 10 ms or more.
ME-LPM-SSM-10
8 a.m. at Day 2
Marking with
the time at
ON
(3 p.m. at Day 1)
Re-dating
T1
T1
Day 2
(Marking with the time
at 8 a.m. at Day 2)
T1
103