3-6-7 Registered character strings: RKS

Sets the character string used with the "Registered characters" function that switches characters by I/O input.
⿎ Setting request data / response data for readout
Start
Sub
RKS
code
command
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
RKS
R
code
⿎ Data description
Data length
Name
[byte]
Data number
Registered
Min. 0
characters
Max. 18
Total data length
Max. 21
• Refer to "2-3-5 Character data input method" (P.37) for details on the character input method and character types with
input restrictions.
⿎ Example of command settings
Condition:
Data number = 4, Registered characters = abcd
• Setting
Transmission data
• Readout
Transmission data
Response data
86
[Data number] [Registered characters]
Max. 21-byte
[Data number]
3-byte
Data contents
I/O input format
4-bit x 4 D0 to 3
D4 to 7
3
D8 to 11
D12 to 15
8-bit x 2 D0 to 7
D8 to 15
The number of input characters
allowed: Max. 9 characters
Input Method: ASCII code or Shift JIS
code (can be mixed)
Variable length.
[STX]
RKS
[STX]
RKS
[STX]
RKS
ME-LP-GS-SR-COMP-3
(Check
(Check
End
sum)
code
Setting range
"000"–"015"
Data number which sets characters. The
"016"–"031"
setting range varies depending on the I/O
"032"–"047"
input format.
"048"–"063"
"000"–"255"
"256"–"511"
• Use the ASCII code to specify one-byte
characters (single byte characters).
• Use the Shift JIS code to specify two-byte
characters (double byte characters).
• Specify 0-byte for data length to delete
characters.
S
004abcd
[CR]
R
004
[CR]
A
004abcd
[CR]
End
sum)
code