Summary of Contents for Panasonic Aicure ANUP5255V2

  • Page 1 Aicure ANUP5255V2 UV-Curing System Operation Manual Matsushita Electric Works Machine & Vision, Ltd.
  • Page 2 Introduction Thank you for purchasing the Aicure Spot Type UV-Curing System. To ensure correct use, read this Manual carefully before using the Aicure. Precautions for Safe Use To prevent injury and accidents, be sure to observe the following instructions. Carefully read this manual before installing, operating, or inspecting the Aicure for proper use. Before using the Aicure, the operators must have a thorough understanding of the equipment, safety information, and miscellaneous cautions on its use.
  • Page 3 Precautions when using the Aicure (1) Use only a power source that supplies the voltage and frequency specified on the product frame or in this manual. Otherwise, burns may be caused. (2) Use this product under the following operating conditions; otherwise, the product life may be shortened.
  • Page 5: Table Of Contents

    Contents 1 Features of the Aicure ANUP5255V2 ....................2 2 Basic procedures of use........................4 3 Product configuration ........................6 4 Exterior features..........................7 5 Aicure assembly ..........................9 Installation of the lamp ......................9 Installation of the light guide fiber unit..................12 Power cord connection ......................13 6 Installation ............................14...
  • Page 6: Features Of The Aicure Anup5255V2

    Aicure ANUP5255V2 Features of the Aicure ANUP5255V2 1 Features of the Aicure ANUP5255V2 Aicure ANUP5255V2 is a UV-ray curing machine that features optical feedback control and programmable UV irradiation systems and provides optimum and reliable curing, bonding, and sealing. Optimum curing for each type of resin and objects (Programmable UV irradiation) You can select and change the UV settings for irradiation intensity, time, and pattern at will to optimize them for the type of resin to be cured and the object.
  • Page 7 Aicure ANUP5255V2 Features of the Aicure ANUP5255V2 Optical feedback control The UV sensor monitors the irradiation amount, and the control circuit controls the intensity control board by feedback control to keep the intensity of UV rays constant. This function automatically prevents any decrease in UV intensity caused by deterioration of the lamp, eliminating the step of changing the irradiation time setting, which up to now has been required.
  • Page 8: Basic Procedures Of Use

    Basic procedures of use 2 Basic procedures of use This section covers the basic procedures of using the AICURE ANUP5255V2. * Be sure to read “Safety Precautions”, “Contents of Product Package”, “Exterior Features”, and “Precautions for Use” before using the AICURE.
  • Page 9 Aicure ANUP5255V2 Basic procedures of use ▼ UV irradiation Power ON (The lamp turns on.) Page 16) UV irradiation ( Page 39) Intensity check UV irradiation (auto control) UV irradiation (manual control) LED indication Displaying the time and other settings Power OFF (The lamp turns off.)
  • Page 10: Product Configuration

    Aicure ANUP5255V2 Product configuration 3 Product configuration Check that the following items are included in the package. Lamp: 1 (included) Power cord: 1 (attachment) Aicure unit ANUP5255V2 (A spare fuse is supplied in the power plug.) Operation manual: 1 (This manual, included)
  • Page 11: Exterior Features

    Aicure ANUP5255V2 Exterior features 4 Exterior features Front Right-hand cover Fiber unit mount ring Light guide fiber unit (This Figure shows ANUP5051.) Monitor fiber mount ring LCD panel Displays operation "▲" button conditions, settings, and "▼" button error messages. Used for screen switching and setting entry.
  • Page 12 Aicure ANUP5255V2 Exterior features Rear Left-hand cover Fuse holder (Refer to Page 68) Cooling fan air outlet AC input connector (100 to 240 V AC, 50/60 Hz) Ground terminal External terminals To be connected with external equipment (personal computer, PLC, etc.) to transmit/receive control signals.
  • Page 13: Aicure Assembly

    Aicure ANUP5255V2 Aicure assembly 5 Aicure assembly Turn the POWER switch off (O) and unplug the power cord before assembling the Caution: Aicure. 5.1 Installation of the lamp Do not touch the lamp with the bare hands. When installing the lamp, Caution: wear clean gloves or use gauze.
  • Page 14 Aicure ANUP5255V2 Aicure assembly Insert the lamp in the hole of the lamp-mounting base with its negative terminal facing upwards. (Aicure side: D-Sub 15 pins, female) Keep dust and burrs away from the space between the flange of the Caution: lamp and the base.
  • Page 15 Aicure ANUP5255V2 Aicure assembly Remove the bottom screw, install the positive lead wire (long) to the lamp shaft, and secure the wire with the removed screw. Positive lead wire Lamp (bottom) Negative lead wire Positive lead wire • Make sure not to mistake the positive and negative polarities of Caution: the lead wires when connecting them.
  • Page 16: Installation Of The Light Guide Fiber Unit

    Aicure ANUP5255V2 Aicure assembly 5.2 Installation of the light guide fiber unit Loosen the screw on the fiber unit mount ring at the front of the unit Insert the light guide fiber unit into the fiber unit mount ring as far as it will go and secure the unit with the screw.
  • Page 17: Power Cord Connection

    Aicure ANUP5255V2 Aicure assembly Loosen the screw on the monitor fiber mount ring. Insert the UV intensity monitor fiber into the monitor fiber mount ring as far as it will go and secure the unit with the screw loosened in Step 3.
  • Page 18: Installation

    Aicure ANUP5255V2 Installation 6 Installation Install the Aicure ANUP5255V2 as instructed below. 6.1 Installation conditions (1) Ambient temperature: 10 to 40 °C (2) Relative humidity: 80% or lower (with no condensation) (3) Set the rubber feet on a flat horizontal surface.
  • Page 19: Installation

    Aicure ANUP5255V2 Installation 6.2 Installation The irradiation distance should be set according to the size of the irradiated area of a workpiece (irradiation diameter) and the intensity of UV irradiation. For the relationship between the irradiation distance and the irradiation diameter, see the table at the Page 72.
  • Page 20: Power On/Off

    Aicure ANUP5255V2 Power ON/OFF 7 Power ON/OFF 7.1 Power ON Turn the “POWER” switch to the ON position (I). After the intensity control plate returns to the origin, the “Main Screen” appears. UV control UV intensity Mnual intensity control Back Next Press the “LAMP ON/OFF”...
  • Page 21: Setting

    Aicure ANUP5255V2 Setting 8 Setting When using the AICURE, set the operating conditions and the method of UV irradiation. 8.1 About the setting mode Setting should be done in the “Setting Mode”. Use the following procedures to establish the “Setting Mode”.
  • Page 22 Aicure ANUP5255V2 Setting About the setting mode screen Setting mode Reference intensity setting Calibration setting Back Next The functions of the “▲”, “▼” and “SET” buttons vary depending on the screen. The three buttons should be operated according to the functions shown in the lower part of each screen.
  • Page 23 Aicure ANUP5255V2 Setting Screen flow in the setting mode Press the “▲” and “▼” buttons on the first screen and subsequent screens of the setting mode to select a desired setting item. When using for the first time, set all items sequentially from the first one.
  • Page 24: Details Of Setting Items

    Aicure ANUP5255V2 Setting 8.2 Details of setting items ■Reference intensity setting and calibration setting (To be performed with the lamp illuminated and stabilized) The intensity of UV irradiation greatly varies depending on the fiber used, installation state, etc. For that reason, perform “reference intensity setting” in the actual installation state to match the display intensity with the actual intensity.
  • Page 25 Aicure ANUP5255V2 Setting After the shutter is opened, measure the intensity of UV irradiation. Immediately after measuring, press the ”MANUAL” switch to close the shutter. Match the “reference intensity” indicated value with the measured intensity of UV irradiation by using the “▲”...
  • Page 26 Aicure ANUP5255V2 Setting ②Calibration “Calibration” should be performed upon execution of “Reference Intensity Setting”. After “Reference Intensity Setting” terminates, press the “SET” button. Calibration Clear Cancel ▼ ▲ Clear Back ▲ (Clear) Clears the set value on “Reference Intensity Setting”, and returns to the “Reference Intensity Setting/Calibration Setting”...
  • Page 27 Aicure ANUP5255V2 Setting After the shutter is opened ("SHUTTER CLOSE" will be indicated), measure the intensity of UV irradiation. Immediately after measuring, press the "MANUAL" switch to close the shutter. ("SHUTTER CLOSE" will disappear). Match the “intensity input” indicated value with the measured intensity of UV irradiation by using the “▲”...
  • Page 28: Intensity Selection

    Aicure ANUP5255V2 Setting Intensity Selection The machine is capable of switching the intensity, duration, and pattern of UV irradiation directed to the workpiece. Here, select a UV irradiation pattern to execute. Reference: “Intensity Selection” can be set by communication through the external device connected to the RS-232-C terminal.
  • Page 29 Aicure ANUP5255V2 Setting Four-step: Select four from among the patterns: UV1 to UV4. Intensity (When U1 to UV3 are selected) Interval irradiation (UV5) ② An interval after completion of the first-step UV irradiation, the second-step UV irradiation is executed. The intensity, duration, and interval of UV irradiation should be set in “Special Intensity”.
  • Page 30 Aicure ANUP5255V2 Setting Select a UV irradiation pattern to execute. Enter the “Intensity Selection” screen. Setting mode Intensity selection Special intensity Back Next ▲ (Back) Moves to the option immediately above the current option. ▼ (Next) Moves to the option immediately below the current option.
  • Page 31: Intensity Setting

    Aicure ANUP5255V2 Setting Intensity Setting When executing “One- to four-step irradiation”, set the intensity and duration of UV irradiation for each step. “Intensity Selection” can be set by communication through the external device Reference: connected to the RS-232-C terminal. See Page 57.
  • Page 32 Aicure ANUP5255V2 Setting Set the “Intensity” value (mW) with the “▲” and “▼” buttons, and press the “SET” button to determine. [Setting range: 0001 to 9999] Setting mode Intensity setting 0500 *(1) T0003 T0003 0800 T0003 1000 T0003 Down ▲ (Up) Increases the indicated value.
  • Page 33: Special Intensity

    Aicure ANUP5255V2 Setting ■Special Intensity When executing “Interval irradiation” or “Analog irradiation”, set the intensity and duration of UV irradiation. “Special Intensity” can be set by communication through the external device Reference: connected to the RS-232-C terminal. See Page 54.
  • Page 34 Aicure ANUP5255V2 Setting Set the “UV Intensity” (mW) and “Irradiation Time” (s) with the “▲” and “▼” buttons, and press the “SET” button to determine. “Interval Irradiation” (UV5) and “Analog Irradiation” (UV6) have different setting items. Set the items in the following order.
  • Page 35: Manual Intensity Control

    Aicure ANUP5255V2 Setting After the completion of “Special Intensity” setting, press the “▲” button (Back) to return to the “Special Intensity” screen. ■Manual intensity control This function allows the manual opening and closing of the intensity control shutter, and with the shutter open, measures and displays the intensity of UV irradiation at the opening (fiber connection).
  • Page 36 Aicure ANUP5255V2 Setting Press the “MANUAL” switch to open the shutter, and conduct UV irradiation. Setting mode Manual intensity control 100% Displayed after UV intensity 3000 mW measurement Close Open ▲ (Close) Moves the intensity control shutter in the direction that “closes” it. (The number of pulses is incremented.)
  • Page 37: Shutter Timer/Lanmp-Change Time

    Aicure ANUP5255V2 Setting ■Shutter Timer/Lamp-Change Time With UV control OFF, press the “AUTO” button, and set the duration of UV irradiation (shutter “open” time). Subsequently, set the lamp-change time to display the “Change” message when the lamp life approaches. ①Shutter timer Call up the “Shutter Timer/Lamp-Change Time”...
  • Page 38 Aicure ANUP5255V2 Setting ②Lamp-Change Time Whenever using for the first time, and changing the lamp, perform this setting operation. ・After the start of use, do not change the setting except on lamp change. Caution: ・On lamp change, conduct “Clearing the cumulative lamp ON time” on the main screen, before this setting operation.
  • Page 39: Address Setting/Language Switching

    Aicure ANUP5255V2 Setting ■Address Setting/Language Switching “Address setting” should be done when multiple machines are connected to one personal computer. “Language switching” should be done when characters are displayed in English on the LCD panel. ①Address setting When the machine is controlled by an external device such as a personal computer, connected to the RS-232-C terminal of the machine, set an address (device number) for the machine.
  • Page 40 Aicure ANUP5255V2 Setting ②Language switching The language used to display on the LCD panel can be selected between Japanese and English. Every time the “▼” button is pressed, the language is switched between “Japanese” and “English”. Setting mode Language switching...
  • Page 41: Origin Return

    Aicure ANUP5255V2 Setting ■Origin Return This function returns the intensity control shutter to its origin. The origin is the position corresponding to the intensity control rate of 100%. Call back the “Origin Return” screen and press the “SET” button to conduct origin return.
  • Page 42: Control (Switchin Between Auto And Manual)

    Aicure ANUP5255V2 Setting ■Control (Switching between Auto and Manual) This function switches UV control between “Auto and Manual”. Call up the “Control” screen. Setting mode Control Back Next ▲ (Back) Moves to the option immediately above the current option. ▼ (Next) Moves to the option immediately below the current option.
  • Page 43: Uv Irradiation

    Aicure ANUP5255V2 UV irradiation 9 UV irradiation 9.1 About UV irradiation UV irradiation is divided into two types: “Auto controlled UV irradiation” and “Manually controlled UV irradiation”. With “Auto controlled UV irradiation”, irradiation is executed according to preset values for intensity and duration of UV irradiation.
  • Page 44 Aicure ANUP5255V2 UV irradiation LCD panel "▲" button Displays operation "▼" button conditions, settings, and Used for screen switching and error messages. setting entry. SET button Confirms entered data. AUTO switch MANUAL switch Starts timer control of the Opens/Closes the irradiation shutter.
  • Page 45: Operation On The Main Screen

    Aicure ANUP5255V2 UV irradiation 9.2 Operation on the main screen UV irradiation, “UV control” ON/OFF switching, and “Intensity check” should be performed on the “main screen”. On “the main screen”, the settings and lamp use status can be checked. UV control OFF...
  • Page 46 Aicure ANUP5255V2 UV irradiation ■Flow on the “main screen” On the first screen of the “main screen”, press the “▲” and “▼” buttons to select an item and switch the screen. UV control OFF UV control: Switches UV control between ON and OFF when Auto UV intensity is selected in the control setting of the setting mode.
  • Page 47 Aicure ANUP5255V2 UV irradiation ■UV control This function switches UV control between ON and OFF. * This is valid when “UV control” is set at “Auto” in the “setting mode”. When “UV control” is set at “Manual”, “Manual” is displayed.
  • Page 48 Aicure ANUP5255V2 UV irradiation ■Intensity check This function adjusts the intensity of UV irradiation to the value selected in “Intensity Selection” in UV control ON situations. It should be executed in the following cases. ・Before UV irradiation is performed for the first time.
  • Page 49 Aicure ANUP5255V2 UV irradiation ■Shutter timer/Illumination time/Change time This function displays the settings and cumulative lamp ON time. With the “▲” and “▼” buttons, select the “Shutter timer/Illumination time/Change time” screen. Shutter timer 0005 Sec Illumination time 1258 Hr Change time...
  • Page 50 Aicure ANUP5255V2 UV irradiation ■Illumination time clearing This function clears (resets) the cumulative lamp ON time when the lamp is attached anew Before using for the first time or when changing the lamp, be sure to perform this clearing operation.
  • Page 51: Setting And Uv Irradiation By External Devices

    10.1 Control items by external devices The AICURE ANUP5255V2 can be controlled through external devices by building it in a sequence circuit and connecting it with external devices such as a personal computer and PLC. To connect, use the connectors on the back of the body.
  • Page 52: Ext.in Parallel Signal Control

    Aicure ANUP5255V2 Setting and UV irradiation by external devices 10.2 EXT.IN parallel signal control UV irradiation can be controlled under parallel signals by connecting the “EXT.IN” terminal on the back of the AICURE body with an external device. ■EXT.IN terminal specifications (Aicure side: D-Sub 15 pins, female) ■Input signal...
  • Page 53 Aicure ANUP5255V2 Setting and UV irradiation by external devices Connection diagram Internal circuit The ratings of the ON contact or transistor used should be as follows: ・ Withstand voltage: 30 V min. ・ Current: 100 mA maximum (24 V) Each control signal should be used independently.
  • Page 54: Rs-232-C Serial Command Control

    Aicure ANUP5255V2 Setting and UV irradiation by external devices 10.3 RS-232-C serial command control Intensity setting and others can be controlled under serial signals by connecting the “RS-232-C” terminal on the back of the AICURE body with an external device (personal computer, PLC).
  • Page 55 Aicure ANUP5255V2 Setting and UV irradiation by external devices ■Basic format Command Identification Header Address Command code Terminator code Text 00~31 % # Response (Normal) Header Address Identification Command code Terminator Text 00~31 code$ % (Abnormal) Header Address Identification Error code Terminator 00~31...
  • Page 56 Aicure ANUP5255V2 Setting and UV irradiation by external devices ■RS232C terminal specifications (Aicure side: D-Sub 9 pins, male) RS232C port of the RS232C port personal computer of the Aicure (DOS/V) Signal name Signal name Pin No. Pin No. Communication specifications...
  • Page 57 Aicure ANUP5255V2 Setting and UV irradiation by external devices ■Command reference RS UV intensity readout Reads the latest UV intensity value measured. Command Address Response Address Intensity value data (4-digit) RK Intensity control rate readout Reads the latest intensity control rate measured.
  • Page 58 Aicure ANUP5255V2 Setting and UV irradiation by external devices RU Intensity setting value readout Reads 6 types of intensity setting values. Command Address Intensity setting type (1-digit) Response (U1 to U4) Intensity rate data Timer setting value Address (4-digit) (4-digit)
  • Page 59 Aicure ANUP5255V2 Setting and UV irradiation by external devices RUS Intensity selection readout Reads the presence or absence of selection of intensity settings U1 to U6. Command Address Response Presence or absence of Address intensity setting 1: Selected/0: Not selected (Ex.) When U1 and U2 are selected...
  • Page 60 Aicure ANUP5255V2 Setting and UV irradiation by external devices RT Lamp ON time readout Reads the cumulative lamp ON time stored in the body, and the presence or absence of lamp-change time. Command Address Response Cumulative Address illumination time Lamp-change time signal 1: ON/0: OFF...
  • Page 61 Aicure ANUP5255V2 Setting and UV irradiation by external devices WUS Intensity selection write Sets UV intensity selection. Command Address UV intensity selection data 1: Selected/0: Not selected (Ex.) When U3 and U4 are selected 001100 Response At normal reception, the command message is returned as-is. However, “#” is changed to “$”.
  • Page 62 Aicure ANUP5255V2 Setting and UV irradiation by external devices WU Intensity setting value write Sets (changes) the UV intensity setting values UV1 to UV6. Command (When set in UV1 to UV4) Irradiation intensity Irradiation intensity Address Setting pattern Response At normal reception, the command message is returned as-is. However, “#” is changed to “$”.
  • Page 63 Aicure ANUP5255V2 Setting and UV irradiation by external devices ②Command (When set in UV5) First-step Address irradiation intensity Setting pattern 「5」 First-step Wait time irradiation time until second-step Second-step Second-step irradiation intensity irradiation time Response At normal reception, the command message is returned as-is. However, “#” is changed to “$”.
  • Page 64 Aicure ANUP5255V2 Setting and UV irradiation by external devices ③(When set in UV6) Command Start irradiation Address intensity Setting pattern 「6」 Total irradiation End irradiation time intensity Response At normal reception, the command message is returned as-is. However, “#” is changed to “$”.
  • Page 65: How To Replace The Lamp

    Aicure ANUP5255V2 How to replace the lamp 11 How to replace the lamp When replacing the lamp, make sure to follow the safety instructions below. Caution: 1. Turn the POWER switch off (O) and unplug the power cord before replacing the lamp.
  • Page 66 Aicure ANUP5255V2 How to replace the Lamp Pull out the lamp from the hole of the lamp-mounting base. Flange Lamp Lamp-mounting base Insert a new lamp in the hole of the lamp-mounting base with its negative terminal facing upwards. Keep dust and burrs from between the flange of the Caution: lamp and the base.
  • Page 67: Clearing The Total Lighting Hours Of The Lamp

    Aicure ANUP5255V2 How to replace the lamp Install the positive lead wire (long) to the lamp shaft and secure it with the screw removed in Step 2. Negative lead wire Positive lead wire ・Make sure not to mistake the "+" and "-" polarities of the Caution: lead wires when connecting them.
  • Page 68: How To Replace The Positive Lead Wire

    Aicure ANUP5255V2 How to replace the Lamp 11.3 How to replace the positive lead wire When replacing the lamp, also replace the positive lead wire if it is damaged. If operation is continued without replacing a damaged positive lead wire, the unit may break.
  • Page 69: How To Install Optional Items

    Aicure ANUP5255V2 How to install optional items 12 How to install optional items UV irradiation intensity can be increased and the temperature of the irradiation target area can be lowered by installing the following optional units in the light guide fiber unit.
  • Page 70: Lowering Temperature Of The Irradiation Target Area (Heat Ray Cutting Filter Unit)

    Aicure ANUP5255V2 How to install optional items 12.2 Lowering temperature of the irradiation target area (Heat ray cutting filter unit) To lower the temperature of the irradiation target area, use the heat ray cutting filter unit. The unit passes rays of short wavelengths (from 254 nm to 436 nm) and filters out heat rays with wavelengths longer than 436 nm.
  • Page 71: Safety Measures

    Aicure ANUP5255V2 Safety measures 13 Safety measures 13.1 Safety circuits This machine is equipped with the following safety circuits to prepare for possible failures and accidents. (1) Prevention of the left-hand cover removal When the left-hand cover is not in place or its screws are loosened, the lamp will not light.
  • Page 72: How To Replace The Fuses

    Aicure ANUP5255V2 Safety measures 13.2 How to replace the fuses The power supply socket has a spare fuse. If the fuse blows, replace it with the spare one. When removing the fuse from the fuse holder, be careful not to apply excessive force Caution: to the glass.
  • Page 73: Troubleshooting

    Aicure ANUP5255V2 Troubleshooting 14 Troubleshooting 14.1 Troubleshooting Trouble Check and Remedy The lamp does not come on (Lamp (1) Is the lamp attached? illumination error). (2) Is the lead wire connected to the positive and negative sides of the lamp?
  • Page 74: Error Message (Red-Backlit Screen And Normal Screen Are Displayed Alternately)

    Aicure ANUP5255V2 Troubleshooting 14.2 Error message (Red-backlit screen and normal screen are displayed alternately) Message Error description Remedy UV intensity error When UV control is ON and (1) Conduct UV the intensity control rate is intensity check. 20% or more, the UV (See Page 41.)
  • Page 75: Specifications And Irradiation Distance Guide

    Aicure ANUP5255V2 Specifications and irradiation distance guide 15 Specifications and irradiation distance guide Input power Single-phase 100 to 240 V AC, 4 A (Max. 2 A at 240 V AC)*1, 50/60 Hz UV lamp Preset type ultrahigh voltage mercury lamp, 250 W (ANUPS 252), Average...
  • Page 76 Aicure ANUP5255V2 Specifications and irradiation distance guide ■Irradiation distance guide ●Relationship between irradiation distances and UV intensities (upper) / irradiation diameters under 70% intensity (lower) (Reference values) [1-mm diameter sensor] Bundle Fiber unit Irradiation distance H (mm) type number ANUP5051...
  • Page 77: Dimensional Drawing

    Aicure ANUP5255V2 Dimensional drawing 16 Dimensional drawing (Output position) Cooling fan Power cable Optical fiber Rubber foot...
  • Page 78: Options List And Spare Parts List

    Aicure ANUP5255V2 Options list and spare parts list 17 Options list and spare parts list ■Options Item Specifications Order number Selectable from combinations of Light guide fiber unit With a heat ray cutting filter unit the bundle diameter at the...
  • Page 79: Manual Revision History

    Aicure ANUP5255V2 Manual revision history Manual No. Date of issue Revised point Oct. 19, 2001 First issue Close attention was paid to the preparation of this manual; however, if you find any errors, please inform us at the following address: Matsushita Electric Works Machine &...