Settings Before External Control - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

1-1-3 Settings before external control

To control the laser marker by using I/O or communication commands, configure the following items in advance at the
system settings of Laser Marker NAVI smart.
1.
Connect the laser marker and Laser Marker NAVI smart online.
2.
Select "System settings" by clicking the screen selection
menu.
3.
Select the "Operation/Information" tab.
4.
Select the switching method of the
remote mode.
• PC configuration software (initial setting)
• I/O
5.
When PC configuration software is
selected, select the remote mode
status at power-on.
• Remote mode ON
• Remote mode OFF (initial setting)
6.
Select the control method for the
following operations between I/O or
communication commands.
As the default, I/O control is selected to all
settings.
• Laser pumping control
• Shutter control
• Guide laser control *1
*1 : Available with LP-GS051(-L) type, LP-350S, LP-RF series and LP-RV series.
• If you want to maintain the compatibility with LP-400/LP-V series, set the operation settings in system settings screen
corresponding with the DIP switch settings on LP-400/LP-V series. For the DIP switch details, refer to "LP-400/V/W
series External control manual".
• To use "Laser Radiation for Measurement Command (SPT)" of the serial communication commands, set the shutter
control method to "communication commands".
• For LP-GS052 type, guide laser cannot be controlled using I/O or communication command.
7.
If you want to use the same command format with the former models of LP-400/LP-V series,
enable "LP-400/V compatibility".