Step & Repeat Settings: Src - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-10-4 Step & repeat settings: SRC
Sets the condition of "Step & repeat" to mark the same marking contents on multiple locations in one file.
• Settings by this command are applied to the object group No. 1000. To the object group No. 1000 the marking data
converted from LP-400/V files and the data set by LP-400/V compatible command mode belong.
• With LP-400/V compatible command mode, the base position of the step & repeat is always set to top left. The settings
of top right, bottom left and bottom right are not available.
• With LP-400/V compatible command mode, "bottom left", "bottom right" and "same as base position" of the counter
stating position cannot be set and readout.
⿎ Setting request data / response data for readout
Start
SRC
command
code
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
SRC
code
⿎ Data description
Name
Step & repeat
ON/OFF
Number of rows
Number of columns
Row step
Column step
116
[Step & repeat ON/OFF] [Number of rows]
Sub
[Number of columns] [Row step] [Column step]
( [X-movement] [Y-movement] ) [Counter behavior]
39-byte, 23-byte or 1-byte
R
(Check sum)
Data length
[byte]
"0": OFF
1
"1": ON
3
"001"–"400"
3
Model
7
LP-GS051(-L)
LP-GS052
LP-RC350S
7
LP-RF200P
LP-RV200P
ME-LP-GS-SR-COMP-3
End code
Data contents
Setting range [mm]
"000.000"–"055.000"
"000.000"–"030.000"
"000.000"–"085.000"
"000.000"–"090.000"
(Check
End code
sum)
Remarks
• Specify "1" to enable Step &
repeat.
• If you specify "0": OFF, end the
data here. It is not necessary to
transmit the subsequent data.
• When the step & repeat is set
to OFF, the subsequent data do
not exist in the response data for
readout.
• The number of rows indicates
the making data repeat count
for Y-direction, and the number
of columns indicates that for
X-direction.
• The upper limit of "Row x
Column" is 10,000.
These are the interval for placing
the marking data of Step & repeat.
The row step is the interval for
Y-direction while the column step is
that for X-direction.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents