14
Key to indicate cables to be changed.
Cables affected
Glow plug links
Fourth glow plug (A1) to glow plug relay (A2)
or glow plug controller (A4)
Starter motor solenoid (A3) to glow plug relay
or glow plug controller
F
Service operations
Remove the induction manifold, see Operation 3-8.
See Operation 14-4 to check the glowplugs.
182
This document has been printed from SPI². Not for Resale
Instructions
Remove original cables 8, 9, and 10 and fit 120 x 0,3 cables
Remove original cable 7 and fit a 120 x 0,3 cable
Remove original cable 6 and fit a 120 x 0,3 cable
C
Workshop Manual, TPD 1392E, issue 3
700 Series