Volume Adjustment
Both the volume controls RVO1 and RV20 in the secondary control circuits
adjust output voltage; RVO1 adjusts the +5 V low voltage output, and RV20
adjusts the -200 V output for plasma.
The voltage at the connector point
of the +5 V low voltage output is set at +5 V +0.1V:
by providing all
the output currents up to the rated values and by adjusting RVO1.
The
voltage at the connector point of the 200 V plasma output is set at 205
+1 V by adjusting RV20.
WARNING
Plasma output is shown below.
Be sure to measure the voltage between the +V and -V terminals
and adjust to -205 +1 V.