Reset Modes

The IN1806 and IN1808 Series scalers have three reset modes (numbered 1,
4, and 5). Use a small screwdriver or stylus to press and hold the recessed
button to advance through the modes. The green Reset LED blinks to indicate each
mode that is enabled (see the Reset Mode Summary table).
NOTE: This
You can also perform resets using the OSD (see
on page 43), SIS commands (see the
(see the IN1806 and IN1808 Series PCS Help file).
ATTENTION:
NOTE: The reset modes listed close all open IP and Telnet connections and all sockets.
Mode
Activation
1
Using an Extron Tweeker or other small
screwdriver, press and hold in the
recessed Reset button for 30 seconds
while applying power to the scaler.
After a mode 1 reset,
NOTE:
update the device with the latest
firmware version. DO NOT
operate with the firmware version
that results from this mode reset.
This temporarily resets the device
to factory default until power is
recycled. To use factory default
firmware, re-upload that version.
4
Press and hold down the Reset button
until the Reset LED blinks three times
(at 9 seconds). Then, press Reset
momentarily (less than 1 second).
5
Press and hold down the Reset button
until the Power LED blinks three times
(approximately 9 seconds). Then,
press Reset momentarily (less than
1 second).
button and LED are located in the lower-right corner of the rear
Reset
panel, and are unrelated to the
IN1808 IPCP models.
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or unit reboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du processeur.
Each mode is a separate function, not a continuation from mode 1 to mode 5.
Reset Mode Summary
The device reverts to the factory default
firmware.
Firmware reverts to the factory default for a
single power cycle.
All user files and settings (drivers, audio
and video adjustments, IP settings, and so
on) are maintained.
NOTE:
firmware or perform a mode 1 reset by
mistake, cycle power to the device to
return to the firmware version running
prior to the reset.
IP settings revert to factory defaults.
Port mapping reverts to factory default.
DHCP turns off.
IP address is set to 192.168.254.254.
Reset LED blinks four times in quick
succession during reset.
The device reverts to the factory defaults
except for firmware.
Mode 4 results are performed.
All user modifiable configurations reset to
default values including IP settings and
real-time adjustments.
All user loaded files are deleted.
The Reset LED blinks 4 times in quick
succession during the reset.
IN1806 and IN1808 Series Scaling Presentation Switchers • Operation
button and LED in the IPCP control panel of the
Reset
Factory Reset
Resets commands
beginning on page 79), and PCS
Result
If you do not want to update the
RESET
RESET
Reset
on the
submenu
Advanced
Purpose/Notes
Use mode 1 to revert
to the factory default
version if incompatibility
issues arise with
user-loaded firmware.
Use mode 4 to reset
all IP settings back to
factory defaults.
Use mode 5 to restart
with the default
configuration. This
is equivalent to SIS
command ZQQQ.
This reset also removes
the initial serial number
password and sets it to
no password.
46

Advertisement

Table of Contents
loading

This manual is also suitable for:

In1808 seriesIn1806In1808In1808 ipcp saIn1808 ipcp ma 70

Table of Contents