Password Messages

If the IN1806 or IN1808 is protected by a password, the following password message
prompts you for the password to access the scaler features.
]
Password
The prompt requires a password, followed by a carriage return. The prompt is repeated if
the correct password is not entered.
For initial setup: On the rear panel of the IN1806 or IN1808, a label is attached
containing the following:
The
set to the device serial number. Passwords are case-sensitive.
This means that, for initial setup, you must enter the serial number of your unit at the
password prompt (the serial number can be found on another label on the rear panel).
This password allows administrator level access.
If the correct password is entered, access is granted and the command prompt is
displayed. If the password is incorrect, the ]
NOTE: Performing a unit factory reset (entering a
mode 5 reset
password, leaving the unit with no password.
After a password change: After the initial access, you can keep the serial number
password or change it. You can also set administrator and user level passwords (see
the
Passwords SIS commands
When you enter the new password correctly, the unit responds with one of the
following, depending on the password entered:
]
Login Administrator
]
Login User
(If the password is not accepted, the
The
Login Administrator
Login User
administrator and user, the unit defaults to administrator privileges.
If the unit is not password-protected, it is ready to accept SIS commands immediately after
it sends the copyright message.

Scaler-initiated Messages

When certain local events occur, such as a change in the status of a contact closure port,
the scaler responds by sending a message to the host. No response is required from the
host. The following messages may be sent:
Reconfig
HplgO
For X7) :
HdcpI
HdcpO
• X5!
IN00
removed) occurs on any input.
X5! is the video signal status for each input. For X5! ,
= input signal detected.
1
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
]
factory-configured
passwords for all accounts on this device have been
via the rear panel
]
]
response represents administrator level access, while the
response represents user level access. If the passwords are the same for both
] A change in the current input frequency was detected.
X@
X7)] A hot plug event was detected on output X@ .
*
= assertion,
= de-assertion
1
2
X!
X4$] A change was detected in the HDCP status of input X! .
*
X@
X4$] A change was detected in the HDCP status of output X@ .
*
X5!] This message appears when a sync change (detected or
*...*
] prompt reappears.
Password
SIS command
ZQQQ
button) removes the serial number
Reset
on page 84).
prompt reappears.)
Password
= no input signal detected,
0
or a
52