Group Master SIS Command and Response Table
Command
Audio Group Master
View Group Master
View soft limits
Group Master Value
Set a group fader value
Example:
View group fader value
Increment a group fader
value
Example:
Decrement a group fader
value
Mute a group
Unmute a group
View group mute status
KEY:
X10)
= Object ID (OID) number
X10!
= Group master group number
X10#
= Soft limit high value in dB
X10$
= Soft limit low value in dB
X10%
= Group master value
X10^
= Increment or decrement value
X10&
= Group master mute status
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
X10!
}
X10#
L
GRPM
In verbose modes 2 and 3:
GrpmL
E
X10!
X10%
}
D
*
GRPM
GrpmD
E
}
D3*-293GRPM
GrpmD3*-293
E
X10!
}
X10&]
D
GRPM
In verbose modes 2 and 3:
GrpmD
E
X10!
X10^
}
D
*
+GRPM
GrpmD
E
}
D3*30+GRPM
GrpmD3*-263
E
X10!
X10^
}
D
*
–GRPM
GrpmD
E
X10!
}
D
*1GRPM
GrpmD
E
X10!
}
D
*0GRPM
GrpmD
E
X10!
}
X10&]
D
GRPM
In verbose modes 2 and 3:
GrpmD
See the
1 through 10.
Preconfigured group. Can alternatively be an alias, which is the
user-defined group name enclosed in braces ({ }).
The valid range for
grouped in
The valid range for
grouped in
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply
by 10. For mute values, use 0 or 1.
Example: -100.0 dB through +80.0 dB is represented by -1000
through 800. The valid range depends on the type of gain block
assigned to the group number (
Value in 0.1 dB steps. For gain value with a resolution to 0.1, multiply
by 10. For mute values, use 0 or 1 as the value.
0 = unmuted, 1 = muted
Additional Description
X10$]
*
View low soft limit
limit
X10!
X10#
X10$]
*
*
X10!
X10%]
*
Set the level of group fader
X10%
]
Set group 3 fader control to -29.3 dB.
View the group fader value.
X10!
X10&]
*
X10!
X10%]
*
Increase the gain value of group
X10^
]
Raise the group 3 fader by 3 dB
from -29.3 dB (set in the previous
example) to -26.3 dB.
X10!
X10%]
*
Decrease the gain value of group
X10^
by
X10!
]
*1
Mute all blocks in group
X10!
]
*0
Unmute all blocks in group
View the group master mute status.
X10!
X10&]
*
Object Identification number table
X10#
must be within the range for the gain block
X10!
.
X10$
must be within the range for the gain block
X10!
.
X10!
).
X10$
and high soft
X10#
X10!
for group
.
X10!
to
.
X10!
X10%
to
.
X10!
X10%
to
.
X10!
.
X10!
.
on page 85.
by
87