Extron electronics IN1806 Series User Manual page 92

Scaling presentation switchers, scalers
Table of Contents

Advertisement

Command
IP Control Port Commands (continued)
IP Setup (continued)
Query the number of open
connections
Reboot networking
Set unit name
Set unit name to factory
default
View unit name
KEY:
X8!
=
Unit name
X8^
=
Number of open connections
X9@
=
Default unit name
Passwords
NOTE:
The initial password set at the factory is the serial number of the unit. However, if the unit is reset (via the ZQQQ SIS
command or the rear panel Reset button), this password is removed.
Set administrator password
View administrator password
Reset (clear) administrator
password
Set user password
View user password
Reset (clear) user password
KEY:
X9!
=
Password
NOTE:
A user password cannot be assigned if no administrative password exists. An E14 error code is returned.
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
}
X8^]
CC
erbose modes 2 and 3:
V
Icc
E
}
2BOOT
Boot2
E X8!
}
CN
Ipn•
E
}
•CN
Ipn•
E
}
X8!]
CN
A text string of up to 32 characters.
A-Z, 0-9, and the hyphen (–) are permitted.
The first character must be a letter.
The last character cannot be a hyphen.
No distinction is made between uppercase and lowercase letters.
Space or blank characters are not permitted.
0-<maximum number of open connections>
Combination of the model name and the last three hexadecimal
character pairs of the unit MAC address.
Example: IN1808-IPCP-SA-14-9A-B0.
E X9!
}
CA
Ipa
E
}
CA
****
In verbose modes 2 and 3:
Ipa•****
E •
}
CA
Ipa
E X9!
}
CU
Ipu
E
}
CU
****
In verbose modes 2 and 3:
Ipu•****
E •
}
CU
Ipu
The original factory configured passwords for all accounts on this
device have been set to the device serial number. If the unit is reset to
factory settings, this password is set to no password.
Length is 1-128 characters.
All human-readable characters are permitted except
The password cannot be a single space.
Passwords are case-sensitive.
If the admin password is cleared, the user password is cleared also.
Additional Description
View the number of open connections.
X8^]
]
Restart the network after IP setting or
DHCP changes.
X8!]
Assign a name for the unit.
X9@]
Reset the unit name to its factory default
name.
View current unit name
• X9!]
Set the administrator password to
] or ]
View the administrator password.
]
]
or Ipa
• ]
Reset or clear the administrator
password.
• X9!]
Set the user password.
] or ]
View the user password. If there is
a valid password, the response is
****
]
]
or Ipu
response is
• ]
Reset or clear the user password.
X8!
.
X9!
]
. If there is no password, the
]
.
|
.
.
84

Advertisement

Table of Contents
loading

This manual is also suitable for:

In1808 seriesIn1806In1808In1808 ipcp saIn1808 ipcp ma 70