Reset Modes: a Brief Summary

The HCR 102 receiver offers the following reset modes:
Use Factory Firmware:
Project Recovery:
Run/Stop Program:
Toggle DHCP Client:
Reset All IP Settings:
Reset to Factory Defaults: Press and hold the HCR 102 front panel Reset button for 9 seconds. After the Power LED
For detailed information on each mode and its use, see the HC 400 Series User Guide at www.extron.com.
Resources

Obtaining Control Drivers

Extron provides an extensive selection of device drivers available on the Extron website. If the system requires a control driver that
is not already available, you can request a new IR, serial (RS-232), or Ethernet driver from Extron.

Obtaining Instructions, Information, and Assistance

Basic setup steps are outlined in this guide. For additional information see the help files and the HC 400 Series User Guide,
available at www.extron.com. If you have questions during installation and setup, call the
Hotline
or the Extron S3 Control Systems Support Hotline (1.800.633.9877).
Press and hold the receiver front panel Reset button (see
location) while applying power to the unit. Keep holding the button down until the Power LED
(
I
) blinks twice, or for 6 seconds, then release the button. The receiver enters factory firmware
mode. Use this mode to revert to factory firmware in the event of a firmware failure.
Do not continue to operate the control processor using the factory firmware version. If you want
to use the factory default firmware version, you must upload that version again.
See the HC 400 Series User Guide for instructions. Use this mode to recover the project in the
event of a lost user name and password.
Hold down the Reset button for about 3 seconds, until the Power LED blinks once. Release
and press the Reset button momentarily (for <1 second) within 1 second*. (*Nothing happens if
the momentary press does not occur within 1 second.) The LED blinks 2 times if the program is
starting. The LED blinks 3 times if the program is stopping. This mode allows you to restart any
scripts or events stopped by an IP settings reset.
Press the Reset button five times (consecutively). Release the button. Do not press the button
within 3 seconds following the fifth press. Use this mode to enable or disable the DHCP client
for the LAN port.
The Reset LED blinks 6 times if the DHCP client is enabled.
The Reset LED blinks 3 times if the DHCP client is disabled.
NOTES:
• DHCP toggle mode is supported on firmware version 1.01 or higher.
• By default DHCP is off and the unit uses a static IP address.
• When you disable the DHCP client by using this mode, the unit reverts to using the
previously-set static IP address.
Press and hold the HCR 102 front panel Reset button for 6 seconds. After the Power LED
blinks twice, release and momentarily press the Reset button. Use this mode to reset all
network settings to factory default values without affecting user-loaded files. This reset mode
also stops any running programs.
blinks three times, release and momentarily press the Reset button within 1 second. Use this
mode to return the receiver to factory default settings. This mode also deletes all user-loaded
files and configurations from the HCR 102, and also the factory default GC configuration. The
basic GC configuration project can be downloaded from the Extron website if you want to
restore it to the unit after a reset.