Extron electronics IN1806 Series User Manual page 97

Scaling presentation switchers, scalers
Table of Contents

Advertisement

DSP SIS Command and Response Table
Command
Gain Level
Set gain level
Example
(Mic/line input 1):
View gain level
Example
(Mic/line input 1):
Example
(HDMI L output
attenuation):
Audio Mute
Audio mute
Audio unmute
Mute status
Phantom Power
Enable phantom power
Disable phantom power
Phantom power status
KEY:
X10)
= Object ID (OID) number
X11)
= Gain value
X11!
= Mute or Phantom power status
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
X10)
X11)
}
G
*
AU
DsG
E
}
G40000*120 AU
DsG40000*120
E
X10)
}
G
AU
DsG
E
}
G40000AU
DsG40000*550
E
}
G60000AU
DsG60000*-55
E
X10)
}
M
*1AU
DsM
E
X10)
}
M
*0AU
DsM
E
X10)
}
M
AU
DsM
E
X10)
}
Z
*1AU
DsZ
E
X10)
}
Z
*0 AU
DsZ
E
X10)
}
Z
AU
DsZ
See the
Levels use a 10x multiplier system with no decimal places. For
example, a level of +10.4 dB would be entered as 104 and a level of
-3.2 dB would be entered as -32.
0 = Disabled, 1 = Enabled
Additional Description
X10)
X11)]
*
Set gain on OID
X11)
]
Set the mic/line input 1 to a level of
+12.0 dB.
X10)
X11)]
Gain on OID
*
X11)
]
Mic/Line input 1 gain is set to
+55.0 dB.
]
HDMI L output attenuation is set to a
value of -5.5 dB.
X10)
]
*1
Mute audio at
X10)
]
*0
Unmute audio at
X10)
X11!]
*
View audio mute status
X10)
]
Phantom power is available only on
*1
Mic/Line Inputs 1 and 2.
X10)
]
*0
X10)
X11!]
*
View Phantom power status
Object Identification number table
X10)
to a value of
dB.
X10)
is set to a value of
dB.
X10)
.
X10)
.
X11!
.
X11!
.
on page 85.