Extron electronics IN1806 Series User Manual page 67

Scaling presentation switchers, scalers
Table of Contents

Advertisement

X4%
=
Video switch effect
X4^
=
HDCP output mode
X4&
=
HDCP notification mode
X4*
=
HDMI output format
X5)
=
Audio input format
Format
Selection
0 = None (input muted) — All audio outputs are muted.
1 = Analog Aux Line input — 5-pole captive screw connector*
2 = LPCM-2Ch digital — Embedded in the HDMI input signal. LPCM-2Ch audio is
requested from the source via EDID.
3 = Multi-Ch digital — Allows any digital audio format requested from the source
via EDID. Audio delay is applied and the signal is re-embedded into the HDMI
output signal.
4 = LPCM-2Ch Auto Aux Line (default) — LPCM-2Ch audio is requested from the
source via EDID. The scaler uses embedded digital audio when it is present, or
defaults to the Aux* Line input when digital is not present.
5 = Multi-Ch Auto Aux Line — Multi-Ch audio is requested from the source via
EDID. The scaler uses embedded digital audio when it is present, or defaults to
the Aux* Line input when digital is not present.
*On the IN1808 Series, when Input 7 or 8 is set to DTP mode, the scaler uses analog audio
from the remote DTP transmitter instead of analog audio from the rear panel of the IN1808.
Analog and Auto formats are not allowed on inputs 7 and 8 of the IN1808 Series when it is
set to XTP mode.
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
0 = Cut through black — The input instantly cuts
to black, then cuts to the newly selected input with
no fading.
1 = Fade through black — The input fades to black
before the newly selected input fades in.
2 = Seamless fade (default) — Displays a final frozen
frame of the previous input while the newly selected
input fades in.
3 = Seamless cut — The last frame of video freezes on
the screen, then cuts to the newly selected input.
Between input switches the audio ramps down and then
up.
0 = Off — Disable all HDCP authentication and encryption
attempts.
1 = Follow input (with a maximum of 10 seconds of
authentication trials, default).
2 = Encrypt output (with a maximum of 10 seconds of
authentication trials.
3 = Follow input (with continuous authentication trials).
4 = Encrypt output (with continuous authentication trials).
0 = Black screen — Notification disabled (mute output)
1 = Green screen with OSD orbiting message (default)
2 = User image with black screen background
0 = Auto — HDMI RGB Full to a CEA sink, or DVI to a
non-CEA sink (default)
1* = DVI — RGB 444, 0-255. Valid for output rates up to
165 MHz
2 = HDMI RGB Full — RGB 444, 0-255
3 = HDMI RGB Limited — RGB 444, 16-235
5 = HDMI YUV 444 Limited — YUV 444, 16-235
7 = HDMI YUV 422 Limited — YUV 422, 16-235
* If the scaler is in DVI mode and a rate greater than
165 MHz is selected, the HDMI output defaults to
HDMI RGB 444 Full.
Details
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

In1808 seriesIn1806In1808In1808 ipcp saIn1808 ipcp ma 70

Table of Contents