Advertisement

Command
Advanced Configuration (continued)
Twisted Pair Protocol
Set input TP type
(IN1808 Series only)
View input TP protocol
(IN1808 Series only)
Set output TP protocol
View output TP protocol
KEY:
X!
= TP input
X6&
= DTP protocol setting
DTP Remote Power Parameters
ATTENTION:
Ensure that the correct remote DTP power setting is used. Sending DTP2 power to a DTP (series 1) endpoint can
result in hardware damage. Enable DTP2 power only to a compatible DTP2 endpoint.
Assurez-vous de bien régler l'alimentation DTP à distance. L'envoi d'une alimentation DTP2 à un point de connexion
DTP (ancienne gamme) peut provoquer des dommages matériels. Assurez une alimentation DTP2 uniquement vers un
point de connexion DTP2 compatible
Set input remote power
(IN1808 Series only)
View input remote power
(IN1808 Series only)
Set output remote power
View output remote power
KEY:
X6^
= DTP remote power status
Resets
System reset (soft reset)
Absolute system reset
Absolute system reset, retain
IP settings
Erase user-supplied web
page and files
24 28
IN1806 and IN1808 Series Scaling Presentation Switchers • SIS Configuration and Control
ASCII Command
Response
(Host to Scaler)
(Scaler to Host)
E
X!
X6&
}
I
*
HDBT
HdbtI
E
X!
}
X6&]
I
HDBT
E
X6&
}
O 2*
HDBT
HdbtO
E
}
X6&]
O 2HDBT
7 = DTP2/XTP input 7, 8 = DTP2/XTP input 8
0 = DTP format (default)
1 = XTP format
2 = HDBaseT format (output only)
E
X!
X6^
}
I
*
RPWR
RpwrI
E
X!
}
X6^]
I
RPWR
E
X6^
}
O 2*
RPWR
RpwrO 2*
E
}
X6^]
O 2 RPWR
0 = No remote power (default)
1 = DTP – 12 VDC
2 = DTP2 – 48 VDC
E
}
ZXXX
Zpx
E
}
ZQQQ
Zpq
E
}
ZY
Zpy
E
}
<filename>EF
Del•<filename>
Additional Description
X!
X6&]
*
Set the TP protocol for input
X!
(
View current TP protocol setting for input
X!
.
X@
X6&]
Set the TP protocol for DTP2/XTP/HDBT
*
Output 1B (2) to
View current TP protocol setting for
output 1B.
X!
X6^]
*
Set the remote power on input
X!
(
View remote power setting for input
X6^]
Set the remote power for output 1B (2)
X6^
to
View remote power setting for output 1B.
]
Reset all device settings to factory
defaults
]
Set all device settings plus DHCP and
the IP address to factory defaults.
DHCP = Off, IP address =
192.168.254.254.
This command also removes the
initial serial number password that is
set at the factory and resets it to no
password.
]
Same as absolute system reset except
that IP address, subnet mask, gateway
address, DHCP, and port mapping are
not reset.
]
X!
to
can be 7 or 8 only.)
X6&
.
X!
can be 7 or 8 only.)
.
X6&
.
X6^
to
.
X!
.
79