EBARA Multi-Stage Dry Vacuum Pumps
5.4.4
Refilling or Replacing the Lubricating Fluid
DANGER
!
Thoroughly purge the pump for at least 15 minutes to remove all toxic gases
before opening the pump for any reason.
CAUTION
!
Before attempting to add any lubricating fluid into the pump, it is imperative that
the secondary reservoirs are drained first. Failure to do so could result in
lubricating fluid being forced into the vacuum area of the pump.
CAUTION
!
When changing or replenishing lubricating fluid, be sure to stop the pump and
allow the pump to return to atmospheric pressure. Because the lubricating fluid
reservoir is under vacuum, the pump can be severely damaged if the lubricating
fluid port plug is removed while the pump is in operation, or not at atmosphere.
5.4.5
Changing the Lubricating Fluid
Primary Reservoir Fill Plugs
Gearbox
Inlet
(Top View)
1. Stop the pump and allow the pressure in the pump to return to atmosphere.
2. Remove the lubricating fluid fill plug and place it on top of the pump.
930601-P
Lubricating Fluid Reservoir Fill / Drain Plugs
Motor
Secondary Reservoir Drain Plugs
Gearbox
(Bottom View)
Primary Reservoir Drain Plugs
Pump Maintenance
Motor
23