Page 1
M o d e l s 3 U / 3 U B End Suction Centrifugal Operating Instructions, Installation & Maintenance Manual EBARA Fluid Handling EBARA International Corporation...
Page 3
Page Safety Specifications and Installation 3U / 3UB Selection Chart 3U / 3UB Specifications 3U / 3UB Type 1 Sectional View and Parts List 3U(B) 65 Type 3 Sectional View and Parts List Installation Instructions Maintenance and Service 3U / 3UB Assembly – 3HP - 15HP 3U / 3UB Assembly –...
Page 4
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance Rules for Safe Installation and Operation (continued) DISCHARGE PIPING – Discharge piping should never be smaller than pump tapping and should preferably be one size larger. A gate valve should always be installed in discharge line for throttling if capacity is not correct. To protect the pump from water hammer and to prevent backflow, a check valve should be installed in the discharge line between the pump and gate valve.
'' ANSI Equivalent 3U50 – 2'' ANSI Equivalent 3UB65 – 2 '' ANSI Equivalent Range of HP 3U – 3 HP to 15 HP 3UB – 7 HP to 30 HP Range of Performance Capacity 13 to 750 GPM at 3450 RPM...
Page 7
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance Sectional view – 3U / 3UB Type 1 117-3 135-1 117-2 117-1 Part No. Part Name Material No. for 1 Unit Casing 304L Stainless Casing cover 304L Stainless Bracket...
Page 8
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance Sectional view – Model 3U 65 Type 3 3U 65-160/20 3U 65-160/25 3U 65-200/20 3U 65-200/25 3U 65-200/30 Part No. Part Name Material No. for 1 Unit Casing 304L Stainless...
Page 9
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance 3U / 3UB Installation Instructions Mounting the Assembly Do not operate the pump unless the assembly is securely and properly mounted. Misalignment of the motor/pump assembly or not having the assembly reasonably level may cause pump vibration, noisy operation, fluid leaks, or air leaks and air locks in the suction pipe.
Page 10
GASKETS - Volute, suction pipe and discharge pipe gaskets should be checked for damage. Replace if necessary. NOTE If replacement parts are ordered, please furnish the following information to your EBARA distributor: 1. Reference Numbers 2. Description of Pump Part 3.
Page 11
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance 3U / 3UB Assembly Instructions Position the pump on its end with the shaft up. The work surface should be level, capable of supporting the motor. WARNING Make certain the motor is not connected to a power source. Do not install or assemble the pump on a motor connected to a power source.
Page 12
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance Assembling the Pump – Models 20HP - 30HP (see page 8 for sectional view) 1. Apply a coat of anti-seize lubricant to the inside of the coupling (005). 2. Insure that key is installed in motor shaft keyway, slide coupling (005) onto shaft. ( Tip: To ease the installation of the coupling tighten the set screw on the side of the coupling.
3U / 3UB EBARA End Suction Centrifugal Operating, Installation, and Maintenance Troubleshooting TROUBLESHOOTING TROUBLE POSSIBLE CAUSE Check power supply circuit. Faulty connection of power supply circuit. Pump does not run. Correct control circuit. Wrong wiring of control circuit. Remove cause of obstruction.