4.3.5.3

Installation options with the antenna multiplexer (2-6 antennas)

You can operate up to six antennas on one reader via the multiplexer.
The data is processed sequentially.
Antenna switchover is performed in time-multiplex mode, so by connecting several antennas
together, the processing time / activation time per antenna is lengthened accordingly.
Figure 4-21
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Configuration example of the antenna multiplexer with ANT D5
RF200 system planning
4.3 Installation guidelines