Transponder
7.12 MDS D324
7.12.4

Technical specifications

Table 7- 30
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Torsion and bending load
232
Technical specifications of MDS D324
UID
User memory
OPT memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D324
8 bytes
992 bytes EEPROM
20 bytes EEPROM
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
6
Epoxy resin
Black
> 25 mm
Inductive, without battery
-25 to +125 ℃
-40 to +140 ℃
IP67
IPx9K
100 g
1)
20 g
1)
Not permitted
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-3AC00
SIMATIC RF200