Technical Data - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

7.9.3

Technical data

Table 7- 22
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Technical specifications for MDS D165
UID
User memory
OPT memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D165
8 bytes
112 bytes EEPROM
20 bytes EEPROM
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
6
Top
Inlay
Antenna
Bottom
White
> 25 mm
Inductive, without battery
-25 to +85 ℃
+20 to +30 ℃
Can be stored for 2 years, determined by the
durability of the adhesive.
IP65
Transponder
7.9 MDS D165
6GT2600-1AB00-0AX0
PET plastic (label
material)
PET plastic (carrier
material)
Aluminum
Double-sided trans-
fer adhesive on sili-
con paper
221

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf200