Ordering Data; Technical Specifications - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Transponder
7.5 MDS D126
7.5.2

Ordering data

Table 7- 10
MDS D126
Table 7- 11
Spacer
7.5.3

Technical specifications

Table 7- 12
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
202
Ordering data for MDS D126
Ordering data for MDS D126 accessories
Technical specifications for the MDS D126
UID
User memory
OPT memory
)
g
Material
Color
Article number
6GT2600-0AE00
Article number
6GT2690-0AL00
SIMATIC MDS D126
8 bytes
112 bytes EEPROM
20 bytes EEPROM
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
years
6
PA6.6 GF
Black
> 25 mm
Inductive, without battery
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-0AE00
SIMATIC RF200