Transponder
7.15 MDS D421
Flush-mounting of MDS D421 in metal with tools
Figure 7-36
b
1
d
1
t
1
All dimensions in mm
Note
Installation instruction
The MDS should not protrude out of the locating hole; it must be flush with the outside
contour.
The mounting instructions of the MDS and the conditions associated with the application
(e.g. peripheral speed, temperature, and use of coolant) must be observed during the
installation.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D421 using your finger; antenna side to the outside (see figure "Flush-
mounting of MDS D421 in metal with tools")
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D421 in metal with tools
248
Flush-mounting of MDS D421 in metal with tools
0.5 x 45°
10 (-0.04.. -0.13)
4.5 (-0... -0.1)
b
0.3 x 45° or R 0.3
2
d
10 (+0.09... 0)
2
t
4.6 (+0.2... 0)
2