Technical Specifications - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Transponder
7.22 MDS D460
7.22.4

Technical specifications

Table 7- 56
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to IEC 68-2-27
Vibration-resistant to IEC 68-2-6
Torsion and bending load
274
Technical specifications for MDS D460
UID
User memory
OPT memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D460
8 bytes
2000 bytes FRAM
16 bytes FRAM
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
6
Epoxy resin
Black
> 10 mm
Inductive, without battery
-25 to +85 ℃
-40 to +100 ℃
IP67
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
50 g
1)
20 g
1)
Not permitted
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-4AB00
SIMATIC RF200