Technical Specifications - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

7.25.5

Technical specifications

Table 7- 62
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
The values for shock and vibration are maximum values and must not be applied continuously.
1)
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Technical data of MDS D522 special version
UID
User memory
)
g
Material
Color
During operation
During transportation and storage
7.25 MDS D522 special variant
SIMATIC MDS D522 special version
8 bytes
8192 bytes FRAM
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
6
Plastic PA 6.6 GF
Black
Inductive, without battery
-25 to +85 ℃
-40 to +100 ℃
IP68
2 hours, 2 bar, +20 °C
50 g
1)
20 g
1)
Not permitted
18 (+0.1) × 5.2 mm
Approx. 1.2 g
Clipping in once (with accompanying tool)
Transponder
6GT2600-5AF00-0AX0