RF200 system planning
4.2 Field data of transponders and readers
Table 4- 10
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
MDS D460
MDS D524
MDS D526
All dimensions in mm.
Table 4- 11
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
MDS D200
MDS D261
MDS D324
MDS D339
MDS D400
MDS D424
MDS D426
MDS D524
MDS D526
All dimensions in mm.
42
Field data SIMATIC RF290R, with ANT D5 (at 4 W)
Length of the transmis-
sion window (L)
320
300
320
320
300
320
320
320
300
320
320
300
320
300
300
320
Field data SIMATIC RF290R, with ANT D6 (at 4 W)
Length of the transmission
window (L)
X direction
Y direction
520
420
500
400
520
420
520
420
500
400
520
420
520
420
520
420
500
400
520
420
520
420
500
400
520
420
500
400
520
420
Operating distance (S
)
a
0 ... 400
0 ... 200
0 ... 350
0 ... 400
0 ... 130
0 ... 350
0 ... 400
0 ... 300
0 ... 200
0 ... 300
0 ... 400
0 ... 200
0 ... 300
0 ... 120
0 ... 200
0 ... 300
Operating distance (S
)
a
0 ... 550
0 ... 220
0 ... 400
0 ... 500
0 ... 130
0 ... 400
0 ... 500
0 ... 350
0 ... 200
0 ... 400
0 ... 500
0 ... 220
0 ... 350
0 ... 220
0 ... 350
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Limit distance (S
)
g
500
280
400
500
180
450
500
400
280
380
500
280
350
160
280
350
Limit distance (S
)
g
650
300
500
600
180
500
600
450
280
480
650
300
400
300
400
SIMATIC RF200