7.8.4
Technical specifications
Table 7- 20
Product type designation
Memory
Memory configuration
•
•
•
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
•
•
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
•
•
•
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Technical specifications for the MDS D160
UID
User memory
OPT memory
)
g
Material
Color
In operation, during write/read access
In operation, outside write/read access
During transportation and storage
SIMATIC MDS D160
8 bytes
•
112 bytes EEPROM
•
20 bytes EEPROM
•
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
years
6
PPS
•
beige
•
> 25 mm
Inductive, without battery
-25 ... +85 °C
•
-40 ... +175 °C
•
from +125 ℃: for 1000 hours, 20% reduction
•
of the limit distance
from +140 ℃: No processing possible
•
at +175 ℃: 100 washing cycles tested
•
at +220 ℃: Tested once for up to 30 seconds
•
-25 to +100 ℃
•
Transponder
7.8 MDS D160
6GT2600-0AB10
217