Transponder
7.10 MDS D200
Read cycles (at < 25 ℃)
Write cycles (at < 25 ℃)
Data retention time (at < 25 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Torsion and bending load
Design, dimensions and weight
Dimensions (L x W x H)
Weight
Type of mounting
The values for shock and vibration are maximum values and must not be applied continuously.
1)
226
)
g
Material
Color
During operation
During transportation and storage
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
5
PET
White
> 25 mm
Inductive, without battery
-20 to +60 ℃
-20 to +60 ℃
IP67
ISO 10373 / ISO 7810
1)
ISO 10373 / ISO 7810
1)
ISO 10373/ISO 7816-1
85 x 54 x 0.8 mm
5 g
Fixing pocket
Glued
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-1AD00-0AX0
SIMATIC RF200