Transponder
7.4 MDS D124
7.4.4
Technical specifications
Table 7- 8
Product type designation
Memory
Memory configuration
•
•
•
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
•
•
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
•
•
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
198
Technical specifications for MDS D124
UID
User memory
OPT memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D124
8 bytes
•
112 bytes EEPROM
•
20 bytes EEPROM
•
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
years
6
PPS
•
Black
•
> 15 mm
Inductive, without battery
-25 to +180 ℃
•
from +125 ℃: 20% reduction in the limit dis-
•
tance
from +140 ℃: No processing possible
•
at +180 ℃: Tested up to 5000 hours or
•
3000 cycles
-40 to +125 ℃
•
IP68
•
2 hours, 2 bar, +20 °C
IPx9K
•
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
100 g
1)
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-0AC10
SIMATIC RF200