System diagnostics

9.1

Error codes of the RF200 readers

Note
Validity of the error codes
The following error codes apply only to RF200 readers with an S-422 interface (CM mode)
You can determine the error code in two ways:
● directly on the reader/CM by counting the flashing pattern of the red error LED
● Through the FB45 variable "error_MOBY".
Table 9- 1
Flashing of
red LED on
reader
00
02
05
06
12
13
19
20
21
24
25
28
30
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
Error codes of the RF200 readers
Error code
Description
(hexa-
decimal)
00
no error
01
Presence error, possible causes:
The active command was not carried out completely
The transponder left the antenna field while the command was
being processed - communication disruption between reader and
transponder
05
Parameterization error, possible causes:
Unknown command
Incorrect parameter
Function not allowed
06
Air interface faulty
0C
The transponder memory cannot be written, possible cause:
Hardware fault (memory faulty)
0D
Error in the specified memory address (access attempted to non-
existent or non-accessible memory areas).
13
Buffer overflow: Insufficient buffer available in the reader for saving
the command
14
Major system fault (hardware fault)
15
Parameter assignment error: faulty parameter in RESET command
18
Only a RESET command is permitted
19
Previous command is still active
1C
Antenna is already switched off/Antenna is already switched on
1E
Incorrect number of characters in frame