A.2.2.9

Technical specifications

Technical specifications
Max. write/read distance
ANT ↔ Transponder (S
Number of channels
Impedance
Power supply
Current consumption
Dimensions (L x W x H)
Length of the connecting cable
Color
Material
Plug-in connections
Max. power (reader input, or per antenna)
Shock resistant according to EN 60721-3-7
Class 7M2
Total shock response spectrum Type II
Vibration according to EN 60721-3-7 Class 7M2
Securing
Tightening torque
(at room temperature)
Ambient temperature
MTBF
Degree of protection according to EN 60529
Weight, approx.
Approvals
SIMATIC RF200
System Manual, 07/2015, J31069-D0227-U001-A9-7618
)
g
Input channels
Output channels
During operation
During transportation and storage
See manual for the relevant antenna
1
6
50 ohm
24 V (± 10 %)
max. 200 mA
240 x 150 x 70 mm
0.4 m
Anthracite
Aluminum die-casting
Power supply: Four-pole M12 / 4 pole round
connector
Reader antenna connector: Single-pole TNC
socket
Antenna connections: 6 x TNC socket
8 W
1.5 g
1.5 g (5 to 500 Hz)
4 M5 screws
≤ 5 Nm
-20 ℃ ... +55 ℃
-25 ℃ ... +70 ℃
2.5 x 10
hours
6
IP65
1.8 kg
CE / FCC / IC