Transponder
7.6 MDS D127
7.6.4

Technical specifications

Table 7- 14
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Torsion and bending load
206
Technical specifications for MDS D127
UID
User memory
OPT memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D127
8 bytes
112 bytes EEPROM
20 bytes EEPROM
> 10
14
> 10
6
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
years
6
PA6
Black
> 0 mm
Inductive, without battery
-25 to +100 ℃
-40 to +125 ℃
IP68
2 hours, 2 bar, +20 °C
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
100 g
1)
20 g
1)
Not permitted