Transponder
7.27 MDS D526
7.27.3

Technical specifications

Table 7- 68
Product type designation
Memory
Memory configuration
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
Recommended distance to metal
Power supply
Permitted ambient conditions
Ambient temperature
Degree of protection to EN 60529
Shock-resistant to IEC 68-2-27
Vibration-resistant to IEC 68-2-6
Torsion and bending load
294
Technical specifications for MDS D526
UID
User memory
)
g
Material
Color
During operation
During transportation and storage
SIMATIC MDS D526
8 bytes
8192 bytes FRAM
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2 x 10
hours
6
Plastic PA 6.6 GF
Black
> 25 mm
Inductive, without battery
-25 to +85 ℃
-40 to +100 ℃
IP68
2 hours, 2 bar, +20 °C
50 g
1)
20 g
1)
Not permitted
System Manual, 07/2015, J31069-D0227-U001-A9-7618