YASKAWA PROFIBUS-DP SI-P3 Technical Manual page 40

Ac drive option
Hide thumbs Also See for PROFIBUS-DP SI-P3:
Table of Contents

Advertisement

8 Parameter Process Data Object Formats
Supported PNU
Supported PNU No.
900
Octet String 12
901
Octet String 20
902
Octet String 4
903
Octet String 12
904
Unsigned 16
905
Octet String 28
907
Octet String 12
908
Octet String 20
909
Octet String 4
910
Octet String 12
911
Unsigned 16
912
Octet String 28
915
Array[10] Unsigned 16
916
Array[10] Unsigned 16
918
Unsigned 16
947
Array[10] Unsigned 16
948
Array[10] Unsigned 16
963
Unsigned 16
964
Unsigned 16
965
Octet String 2
967
V2
968
V2
971
Unsigned 16
<1> The maximum number of times data can be written to the EEPROM used for the drive is 100,000 times. Do not use this write command
frequently.
Example: To read the Drive Command (STW) using PNU900
Command setting
Data type
PKE
IND
PWE
STW
HSW
Response
Data type
PKE
IND
PWE
ZSW
HIW
40
Data type
Write
O
O
O
O
Settings
6384H
5
0
Settings
4384H
5
(STW)
YASKAWA ELECTRIC SIEP C730600 82D YASKAWA AC Drive Option SI-P3 Technical Manual
Read
O
Type 1 PPO-Write
O
Type 2 PPO-Write
O
Type 3 PPO-Write (DP-V1only)
O
Type 4 PPO-Write (DP-V1only)
O
Current PPO-Write
O
Type 5 PPO-Write
O
Type 1 PPO-Read
O
Type 2 PPO-Read
O
Type 3 PPO-Read (DP-V1only)
O
Type 4 PPO-Read (DP-V1only)
O
Current PPO-Read
O
Type 5 PPO-Read
Assign MEMOBUS/Modbus Write Command to PZD
O
in PPO-Write
Assign MEMOBUS/Modbus response to PZD in
O
PPO-Read
O
Node address
O
Fault number
O
Fault time (Elapsed time between fault occurrence)
O
Current baud rate
Device identification
O
for details)
O
Profile code: 0x0302
O
Read or Write Control word
O
Read Status word
Start Store in non-volatile memory (Enter code with
EEPROM)
<1>
Description
6: Request parameter value from array
384H=900 dec (PNU 900)
5th Word data of PPO type 1
N/A
up to Master command
up to Master command
Description
4: Transfer parameter value (array word)
384H=900 dec (PNU 900)
5th Word data of PPO type 1
STW data
up to drive status
up to drive status
Description
(Refer to PNU964 on page 42

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents