YASKAWA PROFIBUS-DP SI-P3 Technical Manual page 25

Ac drive option
Hide thumbs Also See for PROFIBUS-DP SI-P3:
Table of Contents

Advertisement

No.
Name
(Hex.)
F6-32
PROFIBUS-DP Data
(03CD)
Format Selection
<11>
F7-16
(03F4)
Timeout Value
<8> <9>
F7-60
(0780)
PZD1 Write
<8> <9>
F7-61
(0781)
PZD2 Write
<8> <9>
F7-62
(0780)
PZD3 Write
<8> <9>
F7-63
(0783)
PZD4 Write
<8> <9>
F7-64
(0784)
PZD5 Write
<8> <9>
F7-65
(0785)
PZD6 Write
<8> <9>
F7-66
(0786)
PZD7 Write
<8> <9>
F7-67
(0787)
PZD8 Write
<8> <9>
F7-68
(0788)
PZD9 Write
<8> <9>
F7-69
(0789)
PZD10 Write
<8> <9>
F7-70
(078A)
PZD1 Read
<8> <9>
F7-71
(078B)
PZD2 Read
<8> <9>
F7-72
(078C)
PZD3 Read
<8> <9>
F7-73
(078D)
PZD4 Read
<8> <9>
F7-74
(078E)
PZD5 Read
<8> <9>
F7-75
(078F)
PZD6 Read
<8> <9>
F7-76
(0790)
PZD7 Read
<8> <9>
YASKAWA ELECTRIC SIEP C730600 82D YASKAWA AC Drive Option SI-P3 Technical Manual
0: PPO Type
1: Conventional
2: PPO (bit0)
<8> <12> <13>
3: PPO Type (Enter)
<8> <13> <14>
4: Conv (Enter)
<8> <13> <14>
5: PPO (bit0, Enter)
<8> <12> <13> <14>
Sets the detection time for a communications timeout.
Note: Set this parameter to 0.0 to disable the connection timeout function.
Sets MEMOBUS/Modbus address for PZD1 Write (PPO Write).
The value of 0 to 2 enables the PZD1 Write as STW.
Sets MEMOBUS/Modbus address for PZD2 Write (PPO Write).
The value of 0 to 2 enables the PZD2 Write as HSW.
Sets MEMOBUS/Modbus address for PZD3 Write (PPO Write).
The value of 0 to 2 disables the PZD3 Write.
Sets MEMOBUS/Modbus address for PZD4 Write (PPO Write).
The value of 0 to 2 disables the PZD4 Write.
Sets MEMOBUS/Modbus address for PZD5 Write (PPO Write).
The value of 0 to 2 disables the PZD5 Write.
Sets MEMOBUS/Modbus address for PZD6 Write (PPO Write).
The value of 0 to 2 disables the PZD6 Write.
Sets MEMOBUS/Modbus address for PZD7 Write (PPO Write).
The value of 0 to 2 disables the PZD7 Write.
Sets MEMOBUS/Modbus address for PZD8 Write (PPO Write).
The value of 0 to 2 disables the PZD8 Write.
Sets MEMOBUS/Modbus address for PZD9 Write (PPO Write).
The value of 0 to 2 disables the PZD9 Write.
Sets MEMOBUS/Modbus address for PZD10 Write (PPO Write).
The value of 0 to 2 disables the PZD10 Write.
Sets MEMOBUS/Modbus address for PZD1 Read (PPO Read).
The value of 0 to 2 enables the PZD1 Read as ZSW.
Sets MEMOBUS/Modbus address for PZD2 Read (PPO Read).
The value of 0 to 2 enables the PZD2 Read as HIW.
Sets MEMOBUS/Modbus address for PZD3 Read (PPO Read).
The value of 0 to 2 disables the PZD3 Read.
Sets MEMOBUS/Modbus address for PZD4 Read (PPO Read).
The value of 0 to 2 disables the PZD4 Read.
Sets MEMOBUS/Modbus address for PZD5 Read (PPO Read).
The value of 0 to 2 disables the PZD5 Read.
Sets MEMOBUS/Modbus address for PZD6 Read (PPO Read).
The value of 0 to 2 disables the PZD6 Read.
Sets MEMOBUS/Modbus address for PZD7 Read (PPO Read).
The value of 0 to 2 disables the PZD7 Read.
Description
6 Related Parameters
Values
Default: 0
Range: 0 to 5
Default: 0.0 s
Min: 0.0 s
Max: 30.0 s
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
Default: 0H
Min: 0H
Max: FFFFH
25