Output Subsystem - Chroma 62020H-150S Operating & Programming Manual

Programmable dc power supply with solar array simulation
Table of Contents

Advertisement

Query Syntax:
Return Parameter: <NRf+>
Query Example:
Return Example: -1.000000e+02
16.
SAS:SANDIA:PMPp
Description:
Syntax:
Example:
Query Syntax:
Return Parameter: <NRf+>
Query Example:
Return Example: 1.500000e+03
17.
SAS:SANDIA:VMPp
Description:
Syntax:
Example:
Query Syntax:
Return Parameter: <NRf+>
Query Example:
Return Example: 5.000000e+02
5.6.2.9

OUTPUT Subsystem

1.
OUTPut [: STATus]
Description:
Query Syntax:
Parameter:
Return Parameter: OFF | ON
2.
OUTPut : MODE
Description:
Query Syntax:
Parameter:
Example:
Query Syntax:
Query Example:
Return Example:
TABLE Mode Return Example:
OUTPut:MODE TABLE
IVCurve:EDIT <NR1>
IVCurve:VT {...}
IVCurve:IT {...}
IVCurve:SELect <NR1>
OUTPut ON
SAS:SANDIA:TMP -100
SAS:SANDIA:TMP?
SAS:SANDIA:TMP?
Sets the PMPp in SANDIA Mode.
SAS:SANDIA:VMPp <NRf+>
Changes the PMPp to 1500.0 W.
SAS:SANDIA:PMPp 1500
SAS:SANDIA:PMPp?
SAS:SANDIA:PMPp?
Sets the VMPp in SANDIA Mode.
SAS:SANDIA:VMPp <NRf+>
Changes the VMPp to 500.0 V.
SAS:SANDIA:VMPp 500
SAS:SANDIA:VMPp?
SAS:SANDIA:VMPp?
Enables or disables the DC Power Supply output. To stop the output,
set the output voltage to 0 volts.
OUTPut [: STATus]?
OFF | ON
Sets the output mode. The default operating mode is "CVCC".
OUTPut : MODE?
CVCC | TABLE |SAS
OUTPut:MODE CVCC
OUTPut:MODE TABLE
OUTPut:MODE SAS
OUTPut:MODE?
OUTPut: MODE?
CVCC or TABLE or SAS
Remote Operation
5-49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents