Fetch Subsystem - Chroma 62020H-150S Operating & Programming Manual

Programmable dc power supply with solar array simulation
Table of Contents

Advertisement

Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
5.6.2.4

FETCH Subsystem

1.
FETCh:VOLTage?
Description:
Query Syntax:
Return Parameter: <NRf+> [Unit Volt]
Query Example:
Return Example:
2.
FETCh:CURRent?
Description:
Query Syntax:
Return Parameter: <NRf+> [Unit Amp]
Query Example:
Return Example:
3.
FETCh:POWer?
Description:
Query Syntax:
Return Parameter: <NRf+> [Unit Amp]
Query Example:
Return Example:
4.
FETCh:STATus?
Description:
Query Syntax:
Return Parameter: <Arg1><,><Arg2><,><Arg3>
5-36
Measures the output of the Power Supply and returns the real time
voltage.
FETCh:VOLTage?
FETC:VOLT?
9.983100e+00
Measures the output of the Power Supply and returns the real time
current.
FETCh:CURRent?
FETC:CURR?
2.000000e-04
Measures the output of the Power Supply and returns the real time
power.
FETCh:POWer?
FETC:POW?
5.000000e+03
Returns the status code of the Power Supply's state.
FETCh:STATus?
<Arg1>: return warning message 0~65535, 0: no warning, use
binary for the rest and identify the cause of the error.
BIT 0:
OVP
BIT 1:
OCP
BIT 2:
OPP
BIT 3:
Remote Inhibit
BIT 4:
OTP
BIT 5:
FAN_LOCK
BIT 6:
SENSE FAULT
BIT 7:
SERIES FAULT
BIT 8:
Reserved
BIT 9:
AC FAULT
BIT 10: FOLD Back CV to CC
BIT 11: FOLD Back CC to CV
BIT 12: Reserved
BIT 13: Reserved
BIT 14: Reserved
BIT 15: Reserved
<Arg2>: ON|OFF output status at present
<Arg3>: CV or CC status at present