Other Specifications - Chroma 62020H-150S Operating & Programming Manual

Programmable dc power supply with solar array simulation
Table of Contents

Advertisement

Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
Model
Output Ratings
1
Output Voltage
2
Output Current
Output Power
Voltage
Measurement
3
Range
Accuracy
Current
Measurement
3
Range
Accuracy
Output Noise &
Ripple
Voltage
4
Noise(P-P)
Voltage
Ripple(rms)
Current
5
Ripple(rms)
Programming
Response Time
Rise Time:
50%F.S. CC Load
Rise Time: No
Load
Fall Time: 50%F.S.
CC Load
Fall Time: 10%F.S.
CC Load
Fall Time: No Load
Slew Rate Control
Voltage slew rate
6
range
Current slew rate
7
range
Minimum transition
time
1.3.1

Other Specifications

Table 1-2 lists the other specifications of the 62000H. Table 1-3 lists the other specifications
of the A620027 & A620028 models.
1-4
62150H-1000S
0-1000V
0-15A
15000W
200V / 1000V
0.05% + 0.05%F.S.
6A / 15A
0.1% + 0.1%F.S.
2550 mV
1950 mV
270mA
25 ms
25 ms
25 ms
80 ms
3 s
0.001V/ms – 40V/ms
0.001A – 0.1A/ms or
INF
0.5 ms
A620027 Slave Unit
(15kW)
0-600V
0-25A
15000W
120V / 600V
0.05% + 0.05%F.S.
10A / 25A
0.1% + 0.1%F.S.
1500 mV
650 mV
450mA
30ms
30ms
30ms
100ms
1.2s
0.001V/ms - 20V/ms
0.001A/ms - 0.1A/ms,
or INF
0.5ms
A620028 Slave Unit
(15kW)
0-1000V
0-15A
15000W
200V / 1000V
0.05% + 0.05%F.S.
6A / 15A
0.1% + 0.1%F.S.
2550 mV
1950 mV
270mA
25ms
25ms
25ms
80ms
3s
0.001V/ms - 40V/ms
0.001A/ms - 0.1A/ms,
or INF
0.5ms

Hide quick links: