Iv Program Main Screen - Chroma 62020H-150S Operating & Programming Manual

Programmable dc power supply with solar array simulation
Table of Contents

Advertisement

Programmable DC Power Supply (with Solar Array Simulation) 62000H Series
Operating & Programming Manual
4.3.3.2

IV Program Main Screen

When the IV PROGRAM is running, the main screen will display the following information.
Items (1) - (10) in Figure 4-32 are described below.
S E Q S T A T U S =
( 3 )
P R O G . = 1
1 0 0 . 0 0 V
V O C = 1 0 0 . 0 0 V
V M P =
9 0 . 0 0 V
(1) IV-Sequence status: SEQ STATUS shows the IV-Sequence status currently running.
(2) Total Time accumulated: TIME shows the total time accumulated from the execution of
the IV-PROGRAM to the IV-Sequence on the IV-Main Page. The time format is
HOUR:MIN:SEC. The maximum time displayed is 99 hours 59 minutes and 59 seconds.
If the accumulated time exceeds the maximum time display, it will reset to zero and
re-accumulate.
(3) IV-Program Number: PROG. shows the IV-Program Number being executed.
(4) IV-Sequence Number: SEQ. shows the IV-Sequence Number being executed.
(5) IV-FILE Number: FILE. shows the IV-FILE Number being executed.
(6) Count_Remain : CNT_REMAIN shows the number of IV-Programs to be executed.
(7) Open Circuit Voltage: VOC shows the open circuit voltage of the IV-FILE Number being
executed.
(8) Short Circuit Current: ISC shows the short circuit current of the IV-FILE Number being
executed.
(9) Max. Power Voltage: VMP shows the maximum power voltage of the IV-FILE Number
being executed.
(10) Max. Power Current: IMP shows the maximum power current of the IV-FILE Number
being executed.
4-26
A U T O
S E Q . = 1
( 4 )
F I L E . =0
( 7 )
I S C = 1 0 . 0 0 0 A
I M P =
9 . 0 0 0 A
( 9 )
Figure 4-32
T I M E = 0 0 0 : 0 0 : 20
( 1 )
( 5 )
C N T _ R E M A I N = 0
0 . 0 0 0 0 A
( 8 )
( 10 )
( 2 )
( 6 )
0 . 0 W

Hide quick links: