Specific Commands For 62000D Series; Subsystem - Chroma 62000D Series Operating And Programming Manual

Programmable bidirectiona dc power supply
Table of Contents

Advertisement

Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
Bit No. Bit Weight

5.6.2 Specific Commands for 62000D Series

5.6.2.1

Subsystem

ABORt
Description:
Syntax:
5-12
Summary Message
Event Bit (ESB) Bit 5 of
Status Byte Register
Power on Bit. Reboot the power supply can set
7
128
this bit to 1.
6
Always 0.
Command Error Bit. This bit is set to 1 if there is
5
32
any IEEE 488.2 syntax error.
Execution Error Bit. This bit is set to 1 when the
4
16
command parameter is out of valid range or
inconsistent.
Device Dependent Error Bit. This bit is set to 1
3
8
when too many errors have occurred that the
error queue is full.
Queue Error Bit. This bit is set to 1 when reading
2
4
data from the output buffer and no data is
present, or when the data is lost.
1
Always 0.
0
1
Sets all output state to "OFF".
ABORt
7
6
5
4
3
2
1
&
&
&
&
&
&
&
7
6
5
4
3
2
1
Figure 5-2
Table 5-7
Description
Read Standard Event
Status Register by
0
*ESR?
&
Set Standard Event
Status Enable Registor
0
by *ESE?