Technical Data; Control Unit I100 - Roland Double Sheet Detector I100 Manual

For double sided sensors
Table of Contents

Advertisement

B0003308 / 1.4 /
13.02.2013
2

Technical data

Pos: 8 /Doppelblech/Geräte/R100/3 Technische DatenAuswertegerät I100 @ 0\mod_1184853225531_501.doc @ 4200 @
2.1

Control unit I100

Supply voltage
Power consumption
Fuse
Power / switching indication
Display
Ambient temperature
Switching outputs 0-1-2 - Sheet
Temperature depending drift of switching point
Switching capacity
Measurement period
Enclosure
Class of protection I100 / I100-S / I100-IP65
Weight
Connections
Dimensions
Fig. 1: Dimensions of I100 (for mounting on DIN-rail)
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Manual
Double Sheet Detector R100 I100
for pairs of sensors
24 V DC / 110 mA
approx. 2 VA
375 mA slow-blow size 1206 (SMD)
5 LEDs
LCD display, 2 lines, 16 chars. each
0° - 50°C (32° - 122°F) during operation
Opto coupler outputs, output sourcing (PNP)
± 0,02 % / °C
max. 50V, max. 10mA
The min. dwell time of the sheet between the sensors roughly
equals the sensor diameter in milliseconds, e.g. for S28 = 30 ms..
for DIN-rail mounting (EN50022, BS5584)
IP00 / IP54 / IP65
approx. 0,2 kg (0.44 lbs)
Terminal block (I100 / I100-IP65) / Plug connection (I100-S)
125,4 × 103 × 38 mm (H × W × D)
fault
2 sheet
power
1 sheet
0 sheet
103
I100 abmessungen.wmf
Technical data
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Double sheet detector r100

Table of Contents