SSANGYONG RODIUS 2004.09 Manual page 776

Table of Contents

Advertisement

3) Set in Trouble Diagnosis Step 3
In this step, check the position and conditions of recirculation air door and mode door.
Slightly turn the TEMP switch until "3" is displayed on the display window.
If no failure exists, "30" is displayed. If any failure exists, the appropriate trouble code is
displayed.
Slightly turn the TEMP dial to the right to set in the trouble diagnosis step 3
Trouble Code
4) Set in Trouble Diagnosis Step 4
In this step, check the position of actuator door, check the fan speed, and check the
compressor operation.
Slightly turn the TEMP switch in step 3 until "41"
When pressing DEF switch ,
function.
Slightly turn the TEMP dial to the right
to set in the trouble diagnosis step 4
Indication of Step 2.
Starting self diagnosis
is displayed on the display window.
mode changes as shown below in turns to check each
0-5
0000-00
Sensor failure code
blinking (30: no failure)
FATC
RODIUS 2004.09