SSANGYONG RODIUS 2004.09 Manual page 529

Table of Contents

Advertisement

5.AIR CONDITIONER MODULE SENSORS AND ACTUATORS
1) Duct Temperature Sensor
The duct temperature sensor is installed on the top of heater unit. It detects the inside
temperature of duct and transmits the voltage value that is changed according to resistance
value (NTC) to FATC controller.
(1) Inspection
▶If the duct temperature sensor defect code (DTC 3) is set, check as below.
1.
Remove the duct temperature sensor and measure the resistance between terminals on the
sensor connector.
(standard: approx. 25°C, 2.2 kΩ)
In addition, if the resistance is extremely high or, replace the sensor.
2.
If the measured value is out of the specified range, replace the duct temperature sensor. If
the measured value is within the specified range, check as below.
3.
Turn the ignition switch to ON position and measure the voltage to duct temperature sensor
from the FATC controller connector.
(standard: approx. 2 V at 25°C)
4.
If the voltage value cannot be measured, check the circuit for open. If the measured value is
within the specified range, replace the FATC controller.
01-19
6810-20
AIR CONDITIONING SYSTEM
RODIUS 2004.09

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents