0-70
8510-26
B. Armed mode cancellation requirements
-
Unlocking by remote control key or engine starting.
C. Warning operation requirements
-
When opening the door in armed mode
-
When unlocking the door lock switch in armed mode
-
When closing and then opening the door after completion of warning (27 seconds)
D. Warning operation
-
The theft deterrent horn and hazard warning flasher output is "ON" for T3 (27
seconds) with the interval of T2 (1 second).
E. Warning cancellation requirements
-
Cancels warning by using any signal from the remote control key (LOCK, UNLOCK,
START, STOP, PANIC, CHECK) during warning operation.
-
Cancels warning after 27 seconds (remaining period) while the ignition key is turned to
"ON" position.
F. Operation when warning is cancelled
-
The theft deterrent horn and hazard warning flasher outputs are "OFF".